8. Technical Data
The hob is an independent Class 3 built-in unit.
This hob is category II
2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB, IE.
Gas Electric
Natural Gas 20mbar 230 / 400
V
50 Hz
Butane 29mbar
Propane 37mbar
See appliance data badge for test pressures.
Dimensions
Overall height
100 mm;
120 mm including gas connector
Above worktop 50 mm;
Below worktop 50 mm
Overall width
720 mm; see ‘Positioning of Cooker
Overall depth
510 mm
Space for xing
See ‘Positioning of Cooker’
Minimum space above hotplate
650 mm
Connections
Gas Electric
Rp ½ at rear right-hand side
230 / 400 V 50 Hz
Ratings
Hotplate
Natural Gas L.P. Gas
Injector Injector
Triple ring burner 3.5 kW 141 3.5 kW (246g/h) 94
Large burners 3.0 kW 129 3.0 kW (210g/h) 87
Medium burners 1.75 kW 101 1.75 kW (119g/h) 66
Small burner 1.0 kW 77 1.0 kW (70g/h) 50
Gas burner inputs based on Gross Calorific Value.
Maximum total electric load at 230 V: 0.6 W.